Wednesday, June 8, 2022

troubleshooting run-level failed preprocessing

Sometimes preprocessed images for a few runs are just ... wrong. (These failures can be hard to find without looking, one of the reasons I strongly suggest including visual summaries in your QC procedures; make sure you have one that works for your study population and run types.) 

Here's an example of a run with "just wrong" preprocessing that I posted on neurostars: the images are all of the same person and imaging session, but one of the runs came out of the preprocessing seriously distorted.


And here's another: the images from the run at the lower right are clearly tilted and squashed compared to the others:

The above images are temporal means made after fmriprep preprocessing, including transformation to the MNI template anatomy (i.e., _space-MNI152NLin2009cAsym_desc-preproc_bold.nii.gz);  see this post for more details and code. 

How to troubleshoot this type of partial failed preprocessing?

First, note that this is not due to the entire preprocessing pipeline failing: we have the expected set of derivative images for the participant, and everything looks fine for most runs. This suggests that the problem is with not with the pipeline, or that something is unusual about the participant.

fmriprep (and I think most preprocessing pipelines?) is not fully deterministic: if you run the same script twice with the same input files and settings the output images will not be exactly the same. They should be quite similar, but not identical. We have found that sometimes simply rerunning the preprocessing will correct the type of sporadic single-run normalization/alignment failures shown above.

If repeating the preprocessing doesn't fix the failure, or you want to investigate more before rerunning, I suggest checking the "raw" (before preprocessing; as close to the images coming off the scanner as practicable) images for oddities. Simply looking at all the images, comparing those from the run with failed preprocessing and the other (successful) runs from the same session can often make the problem apparent.

Look at the actual functional images of the problematic run (e.g., by loading the DICOMs into mango and viewing as a movie): do you see anything strange? If the problematic run seems to have more-or-less the same orientation, movement, visible blood vessels, etc. as the non-problematic runs for the person, it is unlikely that the source of the problem is the functional run itself and you should keep looking. (If the functional run itself is clearly unusual/full of artifacts, it is most likely simply unusable and should be marked as missing.)

If the functional run seems fine, look at all of the other images used in preprocessing, especially any fieldmaps and single-band reference (SBRef) images. Depending on your acquisition you may have one or more fieldmaps and SBRef images per run, or per set of runs. For the DMCC we use CMRR multiband sequences, so have an SBRef image for every functional run, plus a fieldmap each session. Both the fieldmaps and SBRef images are used in preprocessing, but differently, and if either has artifacts they will affect the preprocessing.

How an artifact in the fieldmap or SBRef affects the preprocessing can be difficult to predict; both can cause similar-looking failures. In the two examples above, the first was due to artifacts in the fieldmaps, the second in the SBRef.

This is a screen capture of three SBRef images from the session shown in the second example. The numbers identify the scans and are in temporal order; image 41 is the SBRef for the affected run (a "tilted" brain); 23 for the correctly-preprocessed run above it. There are dark bands in parts of scan 41 (red), and it looks a bit warped compared to the other two; below is how they look in coronal slices:


All SBRef images look rather odd (here, there's some expected ear dropout (yellow) and encoding direction stretching), but the key is to compare the images for runs in which preprocessing was successful (23 and 32) with those for which it failed (41). The SBRef for 41 is obviously different (red): black striping in the front, and extra stretching in the lowest slices. This striping and stretching in the SBRef (probably from movement) translated to tilting in the preprocessed output above.

What to do about it?

Ideally, you won't collect SBRef or fmaps with strange artifacts; the scanner will work properly and participants will be still. If the images are checked during acquisition it is often possible to repeat problematic scans or fix incorrect settings. This is of course the best solution!

However, sometimes an artifact or movement is not apparent during data collection, the scan can't be repeated, or you are working with an existing dataset and so are stuck with problematic scans. In these cases, I suggest doing something like in this post: look at all of the scans from the session (and other sessions if relevant) and try to determine the extent and source of the problem. 

In the case of the fieldmap artifacts, every fieldmap from the scanning session was affected, but fieldmaps for the same person from two other sessions were fine. We "fixed" the failed preprocessing by building a new BIDS dataset, swapping out bad fieldmaps for good ones and changing the filenames accordingly. Before trying this I checked that the person's head position, distortion, etc. were quite similar between the runs. I do not really recommend this type of image swapping; things can go badly wrong. But it is something to consider if you have similar artifact-filled and good images from the same person and acquisition. With the SBRef image we have another option: SBRef images are not required, so we could delete poor ones (here, scan 41) and repeat the preprocessing without them. 

Neither workaround (swapping or deleting) should be used lightly or often. But it has produced adequate quality images for us in a few cases. To evaluate I look very closely at the resulting preprocessed images and BOLD timecourses, both anatomy and comparing the positive control analysis (see also) results for runs/sessions with normal and workaround preprocessing. For example, confirm that the changes in BOLD timed with your stimuli in particular visual parcels are essentially the same in runs with the different preprocessing. If different visual parcels show the stimulus-caused changes in BOLD depending on preprocessing, the workaround was not successful.

Wednesday, April 22, 2020

observation: variability from running fmriprep multiple times

UPDATE 13 May 2020: I'm now quite sure that the high variability wasn't due to the multiple fmriprep runs, but rather the way I picked the training/testing examples. I'm leaving this post here, but put most of it "below the fold" since my initial interpretation was incorrect. I will eventually release code and more details.

UPDATE 24 April 2020: I realized that there was at least one other possible big contributing factor to the difference between the runs: randomness in how I chose the not-button examples. I'll fix this and see what happens to the SVM results. I previously found extremely similar GLM results between fmriprep versions 1.1.2 and 1.3.2, so the variability here is very possibly only from my randomness in setting up the classification.
 

Wednesday, May 10, 2017

task fMRI motion censoring (scrubbing) #3: impact

 This is the third post in a series, which started with what we were aiming for with the censoring, then how we implemented it for a dataset. Here, I'll show an example of how the censoring changed the GLM results. The GLMs were run in afni, using 3dDeconvolve and TENT functions; the task timing is a complex mixed design (trials embedded in blocks), so the model has both event-related and block-related ("sustained activity") components.

Setting our censoring threshold to FD > 0.9 removed very few frames; less than 2% in most runs, and never more than 12%. I wondered if such a modest amount of censoring would have a noticeable impact, but it looks like it did (which is a bit of a reminder of GLM sensitivity, but that's another issue).

Here's an example person. In the Stroop task for this person 1 frame was censored in the Bas session, 15 in the Pro, and 0 in the Rea. There are more than 1000 frames in each session, so this is not many ant all. The acquisition was with the MB4 paradigm, so we have a pair of runs (AP - PA encoding) for the task each session. Here are motion and FD traces for the person, the Pro session (highest censoring); this is a pretty good set of traces, with the biggest spikes censored at FD > 0.9 (red x).


Now, here are F-statistic images for the same task and person, for the sustained ("block") effect from a GLM. The no-censoring image is first, followed by the with-censoring image. The first row for each is the Bas session, followed by Pro, then Rea; the color scaling is the same in each.




The third (Rea) row is identical in the two images: no censoring (so they better match, since each session went into a separate GLM). The top rows (Bas) look very similar, though the peak values (rng in upper right) vary slightly. The second row (Pro), with the 15 censored frames, varies quite a bit between the two. I found the area marked with the blue arrows particularly interesting: the white matter is much brighter in the no-censoring version, and this white-matter pattern isn't present in the other (less spiky motion) runs, and looks very much like an artifact (not BOLD-ish); particularly the k=44 slice.

Similar effects are seen in the TENTs: high-motion people and sessions tend to have spikier (and less HRF-like) shapes, which is ameliorated a bit by the censoring. There seems to be a bit less ringing with censoring, as well. So, while these are preliminary, qualitative assessments, I'm encouraged that this small amount of censoring may be sensible.

Thursday, May 4, 2017

task fMRI motion censoring (scrubbing) #2: implementing

In the previous post I showed some plots of motion regressors (with enorm and FD) from an ongoing study, with qualitative descriptions and examples of the sort of motion we're seeing. In this post I'll describe some of the literature about motion censoring for task fMRI, and how we decided to implement censoring for this study.

Probably the most directly relevant recent paper for censoring task fMRI datasets, and the one whose recommendations we're broadly following, is Siegel, et. al (2014). They explored the effects of censoring on three datasets at various FD thresholds. As is reasonable, given the great variations in experiments, they refrain from making "universal recommendations", but do provide useful summaries and guidelines.

As in most things, there's no free lunch with censoring: increasing the amount of censoring reduces the number of trials available for response estimation, but hopefully lets those estimates be more reliable. Siegel, et. al (2014) found that a threshold of FD > 0.9 did well in many cases, and generally suggest fairly light censoring - removing the highest-motion frames, not every frame with any movement (see the Discussion section, page 1994). Further, they suggest removing only the above-threshold frames, not adjacent frames (page 1992):
"In a one-factor ANOVA, the FD > 0.9, (f0, b0) mask produced significantly higher zscores than all of the other masks except FD > 1.1 mm (f0,b1) which was not significantly different. On the basis of these results, we do not recommend removing volumes proceeding or following high-motion volumes ..."
Siegel, et. al (2014) didn't attempt to interpolate censored frames, citing the difficulty in accurately interpolating gaps of more than one TR. This strikes me as reasonable, particularly in task designs, where, depending on the analysis, it may be best to simply omit trials with above-threshold movement.

Setting the censoring threshold for any particular study is at least partially subjective, which is unfortunate, given the already-too-many experimenter degrees of freedom. We decided to see if the FD > 0.9 threshold suggested by Siegel, et. al (2014) seemed reasonable: did it capture rare spiky motion, but not oscillations? What percentage of frames were censored? This effort is what let to the images in the previous post: I marked the censored frames on plots of each run's motion, and we judged whether the marked frames seemed reasonable. In our case, no run had more than 12% of the frames censored, and most had less than 2%, so we decided to proceed with the FD > 0.9 threshold.

Looking at papers citing Siegel, et. al (2014), I found one using FD > 0.9 for censoring (Davis, Goldwater, & Giron, 2017), one with FD > 0.8 (O'Hearn, et. al, 2016), and one with FD > 0.5 (Bakkour et. al, 2017). Others mention censoring for motion, but without giving details, and I've heard people mention censoring based on standard deviations of the estimates within the particular dataset. Censoring based on enorm values is pretty similar to the FD used by Siegel, though afni tends to recommend a smaller threshold, such as 0.3, for adult task fMRI. I don't have time to compile a summary of common enorm-based thresholds, but would be interested if someone else finds or creates one!

A final consideration is whether to use only censoring, or censoring plus having the motion estimates as nuisance regressors in the GLM. As summarized in Siegel, et. al (2014), page 1992:
"Motion censoring generally outperformed motion regressions. Censoring at FD > 0.9 mm performed significantly better than the best regression .... To see whether a combination of censoring and regression might most benefit the data, a GLM was created using the default censoring settings and regressions of the derivatives of realignment estimates. The changes in z-score produced by this GLM were not significantly different from censoring alone ..." 
We are currently including 6 motion regressors in the (3dREMLfit) GLMs, plus omitting the censored frames. We might need to reevaluate that choice at some point; we did a bit of looking at including more regressors, but haven't previously considered using only censoring.

Friday, April 21, 2017

task fMRI motion censoring (scrubbing) #1: categorizing

Motion ... whether caused by head movement, other movement, breathing, or something else, it is one of the banes of fMRI. Motion artifacts are a huge issue for resting state fMRI, but not only - it causes big problems in task fMRI as well.The best things to do, of course, is to minimize movement during acquisition, by consistent head positioning, bracing with pads (or other systems). But no system is perfect (or able to eliminate breathing and heart beats), so we need to consider motion in the analyses. Here (as usual, though it's certainly not perfect) I'll use the motion traces (by which I mean the x, y, z, roll, pitch, yaw values produced during realignment and often used as nuisance regressors) as a proxy for motion.

Before deciding on any sort of censoring scheme for a study, it's good to look at the motion from all of the people, to get an idea of general movement categories. This post will show some runs I've decided are representative; exemplars of different sorts of movement. For background, these are individual runs from a cognitive task fMRI study, mostly with an MB4 acquisition scheme (details here).

All of these plots have vertical grey lines at one-minute intervals; the runs are around 12 minutes long. The horizontal green lines show the timing of the three task blocks present in each run; tasks were presented at random times and of varying durations during these blocks. The top pane has the translation (mm) and rotation (degrees) from the Movement_Regressors.txt file produced during (HCP-style) preprocessing. The second pane has the enorm and FD versions of the same motion traces, in mm.

I'll start with really nice traces, then work through to some that are not so nice, illustrating our qualitative categorization. I think it's useful to "calibrate your eyes" in this way to have a baseline understanding of some of the data characteristics before starting serious analyses or data manipulations.

Best possible: freakishly smooth: not even 0.5 mm translation over the entire 12 minute run; the little jiggles are probably related to breathing, and are also incredibly regular.

Not perfect, but very good; isolated spiky movement. This trace has very little drifting, almost entirely regular oscillations. This is the sort of movement that seems exactly suited to motion censoring: quite nice, except for a few short periods. (The frames censored with a threshold of FD > 0.9 are marked by red x.)
 

The next category are traces with prominent oscillations, but otherwise pretty clean (not terribly spiky or drifting), and fairly consistent in magnitude and frequency across the run. We'll be using these types of runs without censoring in our analyses (at least for now).

Finally, are the ones of more questionable quality and utility: numerous spikes, drifting, and/or changes in oscillation magnitude. Frames to be censored at FD > 0.9 are marked, but that's only designed to detect spikes. Slow drifts have generally been considered less problematic for task fMRI than spikes, and we generally have comparatively few drifts in this dataset, regardless.


Spiking and drifting are fairly familiar in motion traces; oscillations, less so. (Though I'm sure this sort of movement existed prior to SMS!) It is certainly possible that the oscillation changes (e.g., third image in last set, second in previous pair) reflect changes in respiration rate (perhaps at least somewhat due to entraining to the task timing), which could affect BOLD in all sorts of problematic ways, and for extended periods. We're actively looking into ways to quantify these sorts of effects and minimize (or at least understand) their impacts, but I don't think there are any simple answers. We have respiration and pulse recordings for most runs, but haven't yet been working with those in detail.